[hermon] Use reset value suitable for ConnectX-3
The programming documentation states that the reset magic value is "0x00000001 (Big Endian)", and the current code matches this by using the value 0x01000000 for the implicitly little-endian writel(). Inspection of the FlexBoot source code reveals an exciting variety of reset values, some suggestive of confusion around endianness. Experimentation suggests that the value 0x01000001 works reliably across a wide range of hardware. Debugged-by: Christian Iversen <ci@iversenit.dk> Signed-off-by: Michael Brown <mcb30@ipxe.org>
This commit is contained in:
@@ -34,7 +34,7 @@ FILE_LICENCE ( GPL2_OR_LATER );
|
||||
|
||||
/* Device reset */
|
||||
#define HERMON_RESET_OFFSET 0x0f0010
|
||||
#define HERMON_RESET_MAGIC 0x01000000UL
|
||||
#define HERMON_RESET_MAGIC 0x01000001UL
|
||||