mirror of
https://github.com/ipxe/ipxe
synced 2026-05-13 03:41:15 +03:00
[uart] Make baud rate a property of the UART
Make the current baud rate (if specified) a property of the UART, to allow the default_serial_console() function to specify the default baud rate as well as the default UART device. Signed-off-by: Michael Brown <mcb30@ipxe.org>
This commit is contained in:
@@ -115,10 +115,9 @@ static void ns16550_flush ( struct uart *uart ) {
|
||||
* Initialise UART
|
||||
*
|
||||
* @v uart UART
|
||||
* @v baud Baud rate, or zero to leave unchanged
|
||||
* @ret rc Return status code
|
||||
*/
|
||||
static int ns16550_init ( struct uart *uart, unsigned int baud ) {
|
||||
static int ns16550_init ( struct uart *uart ) {
|
||||
struct ns16550_uart *ns16550 = uart->priv;
|
||||
uint8_t dlm;
|
||||
uint8_t dll;
|
||||
@@ -137,8 +136,8 @@ static int ns16550_init ( struct uart *uart, unsigned int baud ) {
|
||||
/* Configure divisor and line control register, if applicable */
|
||||
ns16550_write ( ns16550, NS16550_LCR,
|
||||
( NS16550_LCR_8N1 | NS16550_LCR_DLAB ) );
|
||||
if ( baud ) {
|
||||
ns16550->divisor = ( ( ns16550->clock / baud ) /
|
||||
if ( uart->baud ) {
|
||||
ns16550->divisor = ( ( ns16550->clock / uart->baud ) /
|
||||
NS16550_CLK_BIT );
|
||||
dlm = ( ( ns16550->divisor >> 8 ) & 0xff );
|
||||
dll = ( ( ns16550->divisor >> 0 ) & 0xff );
|
||||
|
||||
Reference in New Issue